125 research outputs found

    New techniques for wave-field rendering of polygon-based high-definition CGHs

    Get PDF
    Four novel techniques are introduced into polygon-based high-definition CGHs(PBHD-CGH) that feature the true-fine spatial 3D image accompanied with a strong sensation of depth. The first is algorithm for creatingspecular surfaces based on Phong reflection model. This is very useful for providing a feel of material to polygonal surfaces. The second technique is called digitized holography that replaces the entire processes of classical holography by their digital counterparts. The wave-field of real-existent objects can be optically reconstructed by the digitized holography. This technique makes it possible to edit the 3D scene of holograms or create mixed 3D scene of the real and virtual objects. Another technique for creating PBHD-CGH of real-existent objects is also proposed by a CG-like method using a 3D laser scanner that measures the 3D shape of the object. Finally,a prototype PBHD-CGH is demonstrated for creating landscape scenery. This CGH is intended to reconstruct a scene as if the viewers see mountain scenery through the window given by the CGH.he authors thank Prof. Kanaya for his assistance in 3D scan of live faces. The mesh data for the Venus object is provided courtesy of INRIA by the AIM@SHAPE Shape Repository. This work was supported by the JSPS.KAKENHI (21500114

    Reliability of measurement of endothelial function across multiple institutions and establishment of reference values in Japanese

    Get PDF
    Aims: For the standardization of flow-mediated vasodilatation (FMD) assessment as a clinical tool, validation of its reliability across multiple institutions and the establishment of normal/reference values based on reliable data from multiple institutions are needed. Methods and results: In Study 1, assessment of FMD (scan recording and analysis) using an ultrasonographic semi-automatic measuring system (sFMD) was conducted at 18 participating institutions (sFMD-INST) (n = 981). All of the brachial arterial scans were also analyzed at a core laboratory (sFMD-COLB). After 111 subjects with inadequate sFMD recordings were excluded (n = 880), the correlation between the sFMD-INST and sFMD-COLB improved from R = 0.725 to R = 0.838 (p < 0.001). In Study 2, based on good-quality sFMD data obtained from 6660 subjects without cardiovascular disease (CVD) and 729 subjects with CVD from 27 institutions, reference values of sFMD are proposed by the Framingham risk score (FRS)-based risk categories and according to gender and age. The receiver-operating characteristic curve analysis revealed a significant power of sFMD values in reference ranges to discriminate between subjects with and without CVD (e.g., area under curve = 0.64 in the FRS-low risk group). Conclusions: When the analysis was limited to cases with clear sFMD recordings, the reliability of the sFMD assessment (scan and its analysis) conducted in individual institutions appeared to be acceptable. Reference sFMD values (lower cuff occlusion) for the Japanese population are proposed based on reliable data derived from multiple institutions, and the reference values may identify patients without advanced vascular damage

    Sitagliptin and Carotid Atherosclerosis in Type 2 Diabetes

    Get PDF
    Background Experimental studies have suggested that dipeptidyl peptidase-4 (DPP-4) inhibitors provide cardiovascular protective effects. We performed a randomized study to evaluate the effects of sitagliptin added on to the conventional therapy compared with conventional therapy alone (diet, exercise, and/or drugs, except for incretin-related agents) on the intima-media thickness (IMT) of the carotid artery, a surrogate marker for the evaluation of atherosclerotic cardiovascular disease, in people with type 2 diabetes mellitus (T2DM). Methods and Findings We used a multicenter PROBE (prospective, randomized, open label, blinded endpoint) design. Individuals aged ≥30 y with T2DM (6.2% ≤ HbA1c < 9.4%) were randomly allocated to receive either sitagliptin (25 to 100 mg/d) or conventional therapy. Carotid ultrasound was performed at participating medical centers, and all parameters were measured in a core laboratory. Of the 463 enrolled participants with T2DM, 442 were included in the primary analysis (sitagliptin group, 222; conventional therapy group, 220). Estimated mean (± standard error) common carotid artery IMT at 24 mo of follow-up in the sitagliptin and conventional therapy groups was 0.827 ± 0.007 mm and 0.837 ± 0.007 mm, respectively, with a mean difference of −0.009 mm (97.2% CI −0.028 to 0.011, p = 0.309). HbA1c level at 24 mo was significantly lower with sitagliptin than with conventional therapy (6.56% ± 0.05% versus 6.72%± 0.05%, p = 0.008; group mean difference −0.159, 95% CI −0.278 to −0.041). Episodes of serious hypoglycemia were recorded only in the conventional therapy group, and the rate of other adverse events was not different between the two groups. As it was not a placebo-controlled trial and carotid IMT was measured as a surrogate marker of atherosclerosis, there were some limitations of interpretation. Conclusions In the PROLOGUE study, there was no evidence that treatment with sitagliptin had an additional effect on the progression of carotid IMT in participants with T2DM beyond that achieved with conventional treatment

    A New Serum Biomarker Set to Detect Mild Cognitive Impairment and Alzheimer’s Disease by Peptidome Technology

    Get PDF
    Background: Because dementia is an emerging problem in the world, biochemical markers of cerebrospinal fluid (CSF) and radio-isotopic analyses are helpful for diagnosing Alzheimer’s disease (AD). Although blood sample is more feasible and plausible than CSF or radiological biomarkers for screening potential AD, measurements of serum amyloid- β (Aβ), plasma tau, and serum antibodies for Aβ1 - 42 are not yet well established. Objective: We aimed to identify a new serum biomarker to detect mild cognitive impairment (MCI) and AD in comparison to cognitively healthy control by a new peptidome technology. Methods: With only 1.5μl of serum, we examined a new target plate “BLOTCHIP®” plus a matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF/MS) to discriminate control (n = 100), MCI (n = 60), and AD (n = 99). In some subjects, cognitive Mini-Mental State Examination (MMSE) were compared to positron emission tomography (PET) with Pittsburgh compound B (PiB) and the serum probability of dementia (SPD). The mother proteins of candidate serum peptides were examined in autopsied AD brains. Results: Apart from Aβ or tau, the present study discovered a new diagnostic 4-peptides-set biomarker for discriminating control, MCI, and AD with 87% of sensitivity and 65% of specificity between control and AD (***p  Conclusion: The present serum biomarker set provides a new, rapid, non-invasive, highly quantitative and low-cost clinical application for dementia screening, and also suggests an alternative pathomechanism of AD for neuroinflammation and neurovascular unit damage

    sdLDL-C and Cardiovascular Events

    Get PDF
    Aim: There is little information on the relationships of serum small dense low-density lipoprotein cholesterol (sdLDL-C) levels and serum triglyceride (TG) levels with cardiovascular events in patients with coronary artery disease (CAD) and type 2 diabetes mellitus (DM) who are receiving statins. The aim of this study was to evaluate the relationships of serum TG levels and sdLDL-C levels as residual risks for cardiovascular events in patients with CAD and type 2 DM who were being treated with statins. Methods: The subjects were divided into four groups based on TG levels and sdLDL-C levels: sdLDL-C of <40.0 mg/dL and TG of <150 mg/dL, sdLDL-C of ≥ 40.0 mg/dL and TG of <150 mg/dL, sdLDL-C of <40.0 mg/dL and TG of ≥ 150 mg/dL, and sdLDL-C of ≥ 40.0 mg/dL and TG of ≥ 150 mg/dL. During a median follow-up period of 1419 days, cardiovascular events occurred in 34 patients. Results: The incidences of cardiovascular events were significantly higher in patients with sdLDL-C of ≥ 40.0 mg/dL and TG of <150 mg/dL and in patients with sdLDL-C of ≥ 40.0 mg/dL and TG of ≥ 150 mg/dL, but not in patients with sdLDL-C of <40.0 mg/dL and TG of ≥ 150 mg/dL, than in patients with sdLDL-C of <40.0 mg/dL and TG of <150 mg/dL. Conclusions: Under the condition of treatment with statins, patients with CAD and type 2 DM who had sdLDL-C levels of ≥ 40.0 mg/dL had a high risk for cardiovascular events even though serum TG levels were controlled at <150 mg/dL

    First underground results with NEWAGE-0.3a direction-sensitive dark matter detector

    Full text link
    A direction-sensitive dark matter search experiment at Kamioka underground laboratory with the NEWAGE-0.3a detector was performed. The NEWAGE- 0.3a detector is a gaseous micro-time-projection chamber filled with CF4 gas at 152 Torr. The fiducial volume and target mass are 20*25*31 cm3 and 0.0115 kg, respectively. With an exposure of 0.524 kgdays, improved spin-dependent weakly interacting massive particle (WIMP)-proton cross section limits by a direction-sensitive method were achieved including a new record of 5400 pb for 150 GeV/c2 WIMPs. We studied the remaining background and found that ambient gamma-rays contributed about one-fifth of the remaining background and radioactive contaminants inside the gas chamber contributed the rest.Comment: 21 pages, 8 figures, to appear in Physics Letters

    Diagnostic Criteria of FMD and NID

    Get PDF
    Background - Diagnostic criteria of flow-mediated vasodilation (FMD), an index of endothelial function, and nitroglycerin-induced vasodilation (NID), an index of vascular smooth muscle function, of the brachial artery have not been established. The purpose of this study was to propose diagnostic criteria of FMD and NID for normal endothelial function and normal vascular smooth muscle function. Methods and Results - We investigated the cutoff values of FMD and NID in subjects with (risk group) and those without cardiovascular risk factors or cardiovascular diseases (no-risk group) in 7277 Japanese subjects (mean age 51.4±10.8 years) from the Flow-Mediated Dilation Japan study and the Flow-Mediated Dilatation Japan Registry study for analysis of the cutoff value of FMD and in 1764 Japanese subjects (62.2±16.1 years) from the registry of Hiroshima University Hospital for analysis of the cutoff value of NID. Receiver-operator characteristic curve analysis of FMD to discriminate subjects in the no-risk group from patients in the risk group showed that the optimal cutoff value of FMD to diagnose subjects in the no-risk group was 7.1%. Receiver-operator characteristic curve analysis of NID to discriminate subjects in the no-risk group from patients in the risk group showed that the optimal cutoff value of NID to diagnose subjects in the no-risk group was 15.6%. Conclusions - We propose that the cutoff value for normal endothelial function assessed by FMD of the brachial artery is 7.1% and that the cutoff value for normal vascular smooth muscle function assessed by NID of the brachial artery is 15.6% in Japanese subjects
    corecore